John Crane's Type 28 Dry Gas Seals: How Does It Work?

How Does It Work?

Highest Pressure Non-Contacting, Dry-Running Gas Seal

Type 28 compressor dry-running gas seals have been the industry standard since the early 1980s for gas-handling turbomachinery. Supported by John Crane's patented design features, these seals are non-contacting in operation. During dynamic operation, the mating ring/seat and primary ring/face maintain a sealing gap of approximately 0.0002 in./5 microns, thereby eliminating wear.

These seals eliminate seal oil contamination and reduce maintenance costs and downtime.

John Crane's highly engineered Type 28 series gas seals incorporate patented spiral-groove technology, which provides the most efficient method for lifting and maintaining separation of seal faces during dynamic operation. Grooves on one side of the seal face direct gas inward toward a non-grooved portion of the face. The gas flowing across the face generates a pressure that maintains a minute gap between the faces, optimizing fluid film stiffness and providing the highest possible degree of protection against face contact. Riding only on the load support of a cushion of gas, the seal's film stiffness compensates for varying operating conditions by adjusting the gap and pressure generated to maintain face stability.
John Crane Type 28 seal designs include:
  • Type 28AT Advanced Technology: Designed to excel in low pressure applications, the 28AT is today's most widely used non-contacting, dry running gas seal. Its design pedigree stretches back over 30 years and it has been proven in use on many thousands of installations around the world. The versatility offered by the 28AT makes it ideal for a very wide variety of gas compressor applications.
  • Type 28XP High-Pressure: Offers all the features and benefits of the 28AT, but is optimized to provide reliable performance on higher pressure duties. The 28XP's increased chemical resistance and ability to operate over a wider temperature range has established it as an industry benchmark for reliability.
  • Type 28EXP Extreme High Pressure: John Crane's highly effective solution for sealing gas installations that involve extreme pressures. It has been proven in use in the most challenging and hostile environments and delivers rugged and reliable performance around the world.
  • Type 28ST Steam Turbine: The non-contacting, steam lubricated Type 28ST is an effective sealing solution for small to medium-sized general steam turbine applications. By combining proven rotating groove technology with a high-temperature capability that virtually eliminates leakage of steam along the shaft, it creates an excellent alternative to traditional sealing devices such as segmented carbon bushes and labyrinths.
  • Type 28VL Vaporizing Liquids: Uses the energy of the rotating equipment to vaporize process fluid at a controlled rate, creating a gas film that lubricates the seal faces in applications of extremely low temperature.
  •  

What Sets The Type 28 Series Apart?
  • Accurate centering and balancing: The Type 28 seal mating ring and sleeve use tolerance rings to provide precise centering and cushioning. The seal runs true with a dynamically balanced rotor assembly that eliminates vibration.
  • High-pressure support capability: A metal carrier in the Type 28XP seal controls distortions that can occur under high-pressure loads.
  • Low-drag ring assembly: A custom-fit o-ring and thrust ring set provides extremely low drag and uniform loading to the primary ring surface.
  • Reduced-stress drive points: Low-stress drive flats on the Type 28 seal eliminate stress riser pin holes found in other designs.

Comments

Popular posts from this blog

5 Important Maintenance Metrics and How To Use Them

By  Bryan Christiansen,  Limble CMMS. Source : maintworld.com Effective maintenance of equipment is a critical factor in delivering quality operations that provide timely resources at a minimal cost. However, those in the maintenance field understand that equipment reliability does not come easy.  Organizations need to set quality benchmarks to measure the current effectiveness and predict future performance and use the data obtained to understand where to make improvements.   One way to do this is by using different maintenance metrics to understand the equipment performance. These metrics are very important as they can mean the difference between achieving the overall business goals and explaining how unexpected breakdowns caused yet another production delay.   Maintenance Metrics You Should Be Measuring What are the maintenance metrics? There are two categories of maintenance key performance indicators which include the leading and lagging indicators....

Grounding brush discharge monitoring

In recognition of the possibility of static charge build up in condensing steam turbines, API 612 (2005) specifies that grounding brushes be installed. The electrical flow to ground through these brushes  be monitored and useful information can be extracted. This article carries excerpts from the paper, “Babbitted bearing health assessment” by John K Whalen of John Crane, Thomas D Hess of Chestnut Run, Jim Allen of Nova Chemicals and Jack Craighton of Schneider Electric. Grounding brushes take current from the rotor to ground so that a charge does not build up on the rotor to the point where it discharges to ground though the best path possible – which is usually the closest point between the rotor and stator which is usually (hopefully) the point of minimum film thickness in a bearing. Typically this point of minimum film thickness is found in the active thrust bearing (as will be shown later). Shaft grounding brushes serve two purposes. The brushes are able to transmit modest amo...

WHAT IS THE ULTRASONIC IN-LINE INSPECTION (ILI) PIGGING?

In-line inspection (ILI) of pipelines has established itself as the most efficient tool for evaluating the condition of a pipeline and an indispensable part of pipeline integrity management. Historically, there have been two major technologies used in in-line inspection for corrosion, the magnetic flux leakage (MFL) and ultrasonics (UT), each having their distinct properties and fields of application.  Ultrasonic (UT) ILI has always provided unique quality of information about the pipelines, rendering highest accuracy and tightest measurement tolerances. In the 1990s ultrasonic tools for detection of cracks have become available. Ultrasonic measurement principle: ultrasonic transducer slides along the internal surface of the  pipe wall measuring distance to the wall and the wall thickness (top), yielding the stand-off and the wall  thickness (bottom two B-scans) Ultrasonic (UT) based In Line Inspection tools for all types of liquid filled pipelines. This includes Ultras...

Why Pump Shafts Often Break at the Keyway Area

By NTS Pump shaft failure can lead to significant downtime and repair costs in industrial plants. One of the most common locations for pump shaft failure is at the keyway area. In this article, we will explore the reasons why pump shafts often break at the keyway and what can be done to prevent such failures. The keyway is a high-stress point (weakest point)  on the shaft, where a key is inserted to transmit torque between the shaft and the pump impeller or coupling. During operation, the keyway experiences cyclic loading that creates a bending moment in the shaft, which is concentrated in the keyway area. Over time, this cyclic loading can cause fatigue failure in the shaft material, leading to a fracture at the keyway. In addition to cyclic loading, other factors can contribute to shaft failure at the keyway. Improper keyway design or installation can lead to stress concentrations or inadequate clearance between the key and keyway . Misalignment or overloading can also cause ex...

Pump Shaft Breakage: Case Studies and Solutions

By NTS Pump shaft breakage is a common issue that can cause costly downtime and repairs in various industries. In this article, we will explore several case studies of pump shaft breakage and the solutions implemented to prevent future failures. Case Study 1: Chemical Processing Plant A chemical processing plant experienced repeated pump shaft breakages in their cooling water pumps. Investigation revealed that the pumps were not properly aligned with the motor and had excessive vibration due to the misalignment. This caused the pump shaft to fatigue and break over time. The problem was resolved by realigning the pumps and installing vibration monitoring equipment to detect any future misalignment or excessive vibration. Case Study 2: Wastewater Treatment Plant A wastewater treatment plant had issues with pump shaft breakage in their sludge pumps. The pumps were designed with a straight shaft and lacked a flexible coupling, causing excessive stress and vibration on the pump sha...